Definity OSS Number Setup
command: change system-parameters maintenance
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1061234567
First OSS Endpoint: 12032342705
Abbrev Alarm Report?
y
Second OSS Endpoint:
Abbrev Alarm Report? y
Alarm Origination to OSS Numbers: first-only
Cleared Alarm Notification? y
Suspension Threshold:
5
Restart Notification? y
Test Remote Access Port? y
CPE Alarm Activation Level: minor
Customer Access to INADS Port? y
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 22 : 00 Stop Time: 06 : 00
Daily Maintenance: daily Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no
Product Identification
|
Identifies the switch to AlarmTraq. This must be a 10-digit number starting with
1.
|
First OSS
Endpoint |
Enter the first OSS telephone number to connect with AlarmTraq. Make sure you remember
to include a 9 if connected to a PBX extension.
|
Abbrev Alarm Report
|
Enables the Abbreviated Alarm Report feature for the first OSS. (yes) |
|
Second OSS Endpoint |
Enter the second OSS telephone number to connect with AlarmTraq. Make sure you remember
to include a 9 if connected to a PBX extension.
|
|
Alarm Origination to OSS Numbers |
Indicates one of four options for alarm origination.
both = Major and Minor alarms result in an automatic call to both
administered OSS telephone numbers.
first-only: Major and Minor alarms result in an automatic call
to the first administered OSS number.
neither: alarm origination does not occur; reports are not sent
to either number.
second as-backup: Major and Minor alarms result in an automatic
call to the first administered OSS telephone number.
If calling the first OSS telephone number fails four times, the switch calls the
second administered OSS telephone number until calling the first OSS telephone number
is successful. If Alarm Origination is deactivated, Cleared Alarm Notification and
Restart Notification deactivate, even though they may still be activate in the administration.
|
|
Cleared Alarm Notification |
The switch originates calls to AlarmTraq and sends an alarm resolution message once
all previously-reported Major and Minor alarms are resolved. Activate Alarm Origination
to enable Cleared Alarm Notification.
|
|
Restart Notification |
Enables the switch to originate calls to AlarmTraq and report any system restarts
caused by switch problems. Activate Alarm Origination to enable Restart Notification.
|
|
Suspension Threshold |
Some problems cause alarms to be generated and resolved repeatedly. To detect these
problems, the switch suspends Cleared Alarm Notification when it has reported the
specified number of Cleared Alarm notifications in a 24 hour period.
A suspended Cleared Alarm Notification reactivates with a successfully-completed
“logoff” command, a system reset, or when the threshold is changed. This field is
irrelevant if Cleared Alarm Notification or Alarm Origination are disabled.
|
|
Repeat Dial Interval (MMS) |
Number of minutes that the system must wait before attempting another call origination
to an OSS. Lack of a far-end acknowledgment triggers the timer.
|
See also:
S8700 SNMP Config
IP Office SNMP Config